- ページ 2
パワードライバー ASG BLG-5000-OPC-HTのPDF 操作マニュアルをオンラインで閲覧またはダウンロードできます。ASG BLG-5000-OPC-HT 7 ページ。 With built in screw counter, with built in screw counter and pulse system, for use with screw counter
Operating Procedure
1.
Connect the power cord plug to AC outlet.
2.
Turn power switch on and check if the LED is illuminated. If it
is not lit, contact ASG. After confirming it is lit, turn the power
switch off.
3.
Connect the driver cord to the power source.
4.
Use the torque adjustment nut to select the desired output
setting.
5.
Attach the bit to the screwdriver
6.
Turn the FOR/REV switch to OFF and connect the driver plug to
an AC power outlet.
7.
Turn on power supply and set the power output setting to
1(20V) or 2(30V).
8.
Turn the switch to either FOR or REV to start the screwdriver.
9.
Operate the clutch until the screw is tightened to the set torque
value.
10. Always turn the power off before reversing the rotation
direction setting.
11. When loosening a tightened screw, turn the FOR/REV switch to
REV and loosen in the reverse direction.
Push-to-Start Mode
Unscrew the switch lever shaft screw to detach the switch lever.
Using a tweezer, slide the selection switch to P (Push). Pushing the
selection switch may cause damage. Do not use the screwdriver
with the switch lever shaft screw removed.
Switch Lever
Shaft Screw
Switch Lever
Attaching a Bit
•
Caution: When attaching the bit, always
ensure that the driver FOR/OFF/REV
switch is set to OFF or that the driver
power plug has been removed from the
AC power outlet.
•
Use the correct bit size. To install the bit,
push or pull the joint shaft collar at the
end of the driver upwards and insert the
bit. Check that the bit does not come
loose after you have inserted it.
ASG, Division of Jergens, Inc.
S. Waterloo Road | Cleveland, OH
15700
HIOS BLG-BC1 Series
Operational Manual
L-><-P Select switch
is at the side of this
section
| Phone: (
44110-3898
888) 486-6163
Torque Adjustment Procedure
•
BLG-4000 has two torque adjustment springs – Red spring is
for high torque measurement, white spring is for low torque
measurement.
•
Use the torque adjustment nut to select the desired
output setting. Note that this setting should be taken as
an approximate value. Adjust the setting by loosening the
adjustment nut stopper and adjusting the torque adjustment
nut. When the setting has been made, re-tighten the torque
adjustment nut stopper securely. Repeat this process to
determined the appropriate tightness. Use a torque tester to
verify.
•
BLG-5000: Use an allen wrench to adjust the scale.
Torque adjustment nut
can be turned and moved
manually with this ring
Screw Counter
•
The BLOP-STC3 is a power supply with a screw counter. The
BLOP-SC1 is a screw counter. Please see the operation manual
for these products for more information.
•
BLOP-STC3 Compatible Screwdrivers: BLG-4000-OPC, BLG-5000-
OPCS, BLG-ZERO1, BLG-BC1, BLG-BC2
•
BLOP-SC1: Must be used with an external power supply.
Compatible Screwdrivers: BLG-4000-OPC, BLG-5000-OPCS, BLG-
ZERO1, BLG-BC1, BLG-BC2
•
Note: When a tool with an internal counter is used in
combination with an external counter, the external counter
supersedes the internal counter of the tool. Turn off the
screwdriver's counting function before use.
Repairs
Contact ASG with any questions or concerns at +1-888-486-6163 or
Accessories
•
Bits
•
Torque adjusting spring – BLG-4000 has two torque adjustment
springs – Red spring is for high torque measurement, white
spring is for low torque measurement.
•
Allen wrench
| Fax: (
| Email: [email protected] | Web: www.asg-jergens.com
216) 481-4519
Torque
adjustment
scale