- ページ 4

航空機 ASG 32 ELのPDF フライトマニュアルをオンラインで閲覧またはダウンロードできます。ASG 32 EL 10 ページ。

Flight Manual
Emergency Retraction of the Power-plant
The following emergency retraction procedure can be applied, if the ex-
tended power-plant should fail and the additional drag is a serious danger
for the further flight. A still sound 12V power supply of the power-plant is
required for this.
WARNING
If the emergency procedure is applied, the propeller as well as the
engine compartment doors will be unavoidably severely damaged!
• Power-plant main switch:
• Press and hold the turn-push button of the power-plant instru-
ment and switch power-plant main switch ON simultaneously
(service menu is shown)
• Press the turn-push button once and turn one notch clockwise
(field "retract" is activated)
• Press the turn-push button once (retraction starts)
• Wait approx. 10 seconds
• Press the turn-push button once (retraction stops)
• Power-plant main switch:
Issue:
15.09.2017
Revision:
TN 12 30.10.21 PA
PA
OFF
OFF
Flight Manual
Appr.
3.8a