- ページ 5

産業機器 Doka 582778000のPDF オリジナル取扱説明書をオンラインで閲覧またはダウンロードできます。Doka 582778000 6 ページ。 Shifting carriage tg

Original Operating Instructions Shifting carriage TG
The load is not being raised to the maximum
height
Possible causes:
Not enough hydraulic oil
The load can only be "pumped upwards" with
great difficulty
Possible causes:
The releasing pin is stuck in the control valve (in the
rubber knob or in the valve housing)
The valve control system is faulty (low-pressure-
valve core)
The load is being lowered of its own accord
Possible causes:
Hydraulic tubing is leaking
The valve control system is faulty (low-pressure-
valve core)
The valve-face does not shut tightly (high-pressure
valve core)
The load cannot be lowered
Possible causes:
The setting of the lowering mechanism has been
misadjusted
The releasing pin is stuck in the control valve (in the
rubber knob or in the valve housing)
The valve control system is faulty (low-pressure-
valve core)
The load is being lifted jerkily and/or
"bounces"
Possible causes:
Air trapped in the hydraulic system
Lowering mechanism is not optimally adjusted

Component overview

999260002 - 03/2011
J
9260-801
A Safety catch
B Trigger handle
C Filling opening
D Bleeder screw
E Pump piston
F Valve block
G High-pressure valve core
H Low-pressure valve core
The Formwork Experts
E
F
9260-802
5