EN – TECHNICAL USER GUIDE
INSTALLATION
For optimum mounting of the sensor, use a mounting clips.
The sensor should be placed in a position which is representative of the light level in the house – the light-sensitive area of the sensor is shown in
Figure 1. Sunlight from the outside and objects obstructing incident light should be taken into account.
Examples of mounting are shown in Figure 2.
When demounting variant with M12 connector, the included plug must be mounted.
Figure 4: Connection
If 1:1 compliance with the L 182/19 standard is desired, measurements according to the standard and an adaptation to the output of the DOL 16
sensor with the chosen position must be carried out.
IN DUSTY ENVIRONMENTS, THE SENSOR SHOULD BE PLACED IN A POSITION WHICH ALLOWS FOR EASY CLEANING AT REGULAR
INTERVALS.
TECHNICAL DATA
Measuring range
Accuracy
Output signal (I
)
out
Time constant
Supply Voltage (V
)
supply
Supply Current
Load
Recommended load
Output current
Output impedence
Temperature, operation
IP classification
Cable
Cable connecting (only M12 variant)
Max. cable length
Shipment weight
Measure, shipment
dol-sensors a/s
Hedelund 4, Glyngøre
Output 1
0 – 50 Lux
2 -50 Lux 4 %
at 0 - 40 °C(32 °F – 104 °F)
0.2V / 1 Lux
Typ. 2 Sec.
Max. 15 Sec.
11 – 30 V DC
12 mA no load
55 mA max. load
>500 Ω - < 10 MΩ
≥ 100 kΩ
20 mA per output (current limited)
< 1 Ω
- 40 °C – 60 °C(-40°F - 140°F)
IP 67(NEMA 6)
2 m (6.6 feet) 4 x 0.33mm
M12 female connector with 2m (6.6 feet) 4 x 0.33mm2 (22AWG) cable
100 m 0.82 mm
150 g (5.3oz)
275 × 200 × 20 mm (11 × 8 × 0.8 inch)
7870 Roslev
Denmark
Output 2
0 -1000 Lux
25 -1000 Lux 8 %
at 0 - 40 °C(32 °F – 104 °F)
0.1V / 10Lux
Common
2
(22AWG) cable
2
(328 feet 18AWG)
Tel. +45 72 17 58 88
Fax +45 72 17 59 59
www.dol-sensors.com