application examples
L+
L -
X1
BG5913
(-)
4 light curtains, category 4, auto/manual start; function: 1,3
safety gate 1
S1
S2
X1
S12 S14
BG5913
(-)
48
error indication,
enabling active
4 safety gates with 2 NO contacts; function: 4
LC 1
LC 2
+
+
+
trans-
mitter
-
-
-
OSSD
OSSD
S12 S14
S22 S24
48
error indication,
enabling active
safety gate 2
safety gate 3
S1
S2
S1
S22 S24
S32 S34
LC 3
+
+
+
trans-
trans-
mitter
mitter
-
-
-
OSSD
S32 S34
safety gate 4
S2
S1
S2
S42 S44
58
waiting for start
error
8
LC 4
+
+
trans-
mitter
-
-
OSSD
S42 S44
X2
58
(-)
waiting for start
error
M8949_b
X2
(-)
M8955_b
BG 5913.08/_0_ _ _ / 11.05.09 e