OPTIONS AND ADDITIONAL
INFORMATION
RL-1 Series remote control plates –
general considerations
Cloud RL-1 Series remote control plates are available in three
form factors: two fit single-gang UK or American electrical
back boxes respectively, while the third is a 50 x 50 mm
"Media" module, suitable for "Euro-module" mounting frames
available in most European countries. Back boxes of either
the recessed type or surface-mounting type may be used,
providing they are at least 25 mm deep.
Each plate should be connected to the REMOTE LEVEL
CONTROL port of the relevant zone using twin-core
screened cable as described at "Music Control" on page 11.
The plate terminations are conventional screw terminals and
the REMOTE LEVEL CONTROL port on the mixer is
a 4-pin 5 mm-pitch screw terminal connector. A single plate
may be wired for conventional stereo operation, or two
plates may be wired to control the left and right channels of
a zone independently.
The remote control plates are passive and thus do not draw
any significant current from the mixer.
Control of music source and level via
external DC
It may be necessary in some installations to adjust the
music level in one or more zones from an external control
system (e.g., Crestron, AMX, etc.). If the REMOTE LEVEL
CONTROL ports are not required for RL-1 Series remote
control plates, they may be used to receive DC voltages from
the external system to effect these adjustments.
Music level can be controlled over its full range with a DC
voltage of 0 to +10 V. The pinout of the REMOTE LEVEL
CONTROL port is as follows:
PIN
USE
1
0 V ref.
2
Music level control – Left channel
3
Music level control – Right channel
4
+12 V ref.
To control music level in a zone, apply a DC voltage of
between 0 and +10 V to pins 2 and/or 3, with the 0 V reference
connected to Pin 1. 0 V on pins 2 or 3 corresponds to full
level and +10 V will produce maximum attenuation. Between
these two voltages, the rate of attenuation is approximately
165 mV/dB.
NOTE: If the control voltage source is not isolated from the
power earth, there is a small risk of creating a 'ground loop'
by linking the mixer technical ground (0 V) to the ground (0 V)
of the equipment supplying the control voltages. To minimise
this risk, we suggest that all pieces of equipment be in close
proximity, and supplied from the same power outlet.
Fitting loudspeaker EQ cards
The CX163 is compatible with various popular installed-
sound loudspeakers; a single-channel loudspeaker equalisation
module may be fitted to either zone output or to the Utility
Output, to optimise the frequency response of the channel to
the loudspeaker type being used.
Please
check
the
Cloud
accessories) for makes and models of loudspeakers for which
EQ cards are available.
To install equalisation modules, first remove the top cover
from the CX163 (6 screws). The modules plug into the empty,
white 12-pin connectors on the main PCB. Note that as Zones
1 and 2 are stereo, they have two connectors each, while the
Utility Output has one.
CONNECTOR
CON5
CON4
CON7
CON6
CON3
The connectors on the main PCB have two notches on one
side only; these engage with lugs on the equalisation module's
mating connector to ensure correct orientation. Note that
unlike certain other Cloud units, it is not necessary to remove
any "bypass" jumpers to enable the EQ cards.
See the Appendix section "PCB jumper locations and
settings" at "PCB jumper location and settings" on page 17
for further details. Replace the top cover with the original
screws after fitting.