- ページ 8
消防設備 Akron SAM BOOSTのPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。Akron SAM BOOST 8 ページ。
10. FINAL COMMISSIONING CHECKLIST
INITIAL PASS CRITERIA
□
Verify Display shows SAM BOOST™ Splash screen while Pump in Road
Mode & Transmission in Drive Gear with Two People for Safety
□
Operate Preconnect Valves from Display - Full Open and Full Close
(Not required to be in Pump Gear)
□
Operate Tank-to-Pump Valve from Display - Full Open and Full Close
(Not required to be in Pump Gear)
□
Put into Pump Gear and verify no Warnings appear
□
Increase and Decrease Engine RPM with the Display
(If unable to do so, verify Governor Settings [Password: 00311])
□
Verify Emergency Idle functions with the Display
Press Mode button to revert to PSI Mode
While in PSI Mode, Increase Set Pressure to 100 PSI (or value that
□
increases Engine RPM.) Verify that Pump Set Pressure on Display
matches Master Discharge Gauge Pressure
□
Operate Nozzles to Open the Paired Preconnect Valves
With Two People for Safety, Validate Nozzle Calibration is correct by
□
having one person hold the bail Full Open & the other person at the
display checking Actual Pressure equals Rated Pressure with Full Hose
Length by pressing the Info Button on valve page
□
Validate Nozzle Signal Strength is reading appropriately. This can be
checked by pressing the info button on the valve page
Validate Truck voltage is reading appropriately. This can be checked by
□
pressing the info button on the valve page
(If incorrect, adjust on 06565 password page)
Drain tank while in Tank Mode and trip low tank warning audio & visual.
□
Warning should trip at ¼ tank level
(Validate buzzer operation and tank calibration)
□
Apply hydrant pressure, close tank-to-pump, and validate that nozzle
changes to a blue color
□
Check Engine Oil Pressure & Temperature
Sheet: FSG-MNL-00233
SAM BOOST™ WITH SMART NOZZLE N
Refer to FSG-MNL-00232 for complete listing of Safety Hazards & Warnings
Revision 7 / 10 / 2023
QUICK START GUIDE
P
2