BENCH TEST UNITS - Configuration Mode
The RF units are capable of operating with multiple pairs of units in the same environment. Units on
different channels can operate in the same area with minimal interference to each other.
Unit channel selection is made at the factory and no field settings are necessary.
Up to 8 pairs of units can operate in the same area. . A serial number sticker will be present on the
unit to indicate the paired units. Units matched as a pair will have the same serial number.
During initial setup it is helpful to use the Setup/Config mode. This allows a relative indication of the
radio transmission and reception between units.
Here follows a description of the Setup / Config mode.
Setup / Config mode:
By setting DIP switch 1 to the ON position, the unit is placed in Setup / Config mode. This switch
change can be made at any time. When the switch position is changed, the unit will reset and restart
in the new mode. This is helpful for setup and diagnostic purposes.
In Normal operational mode (DIP switch #1 OFF) the units will remain quiet unless there is a
status change, and will slowly poll each other about every 10 to 15 seconds to check the link
integrity.
The Setup / Config mode places the units in rapid polling sequence to allow troubleshooting and
setup of the communication link.
The Duprex RF units use a quiet protocol when operating in normal mode. Communication between
the Central and Remote unit only occurs when an event requires data transmission or contact needs
to be made to maintain supervision. The RF channel remains quiet most of the time.
During setup or troubleshooting it may be necessary to observe the communication link between the
Central and Remote units. The rapid polling used in the Setup / Config mode can help indicate
whether the units can "See" each other.