- ページ 10

エクステンダー Cypress Suprex SPX-1300のPDF 操作マニュアルをオンラインで閲覧またはダウンロードできます。Cypress Suprex SPX-1300 16 ページ。 Reader extender
Cypress Suprex SPX-1300 にも: 操作マニュアル (17 ページ)

Cypress Suprex SPX-1300 操作マニュアル
6. The Cypress SPX-1300 provides additional data channels to support access control hardware such as door
strikes, tamper alarms, request to exit status, etc. These signals are sent to and from the Remote and Central units
without the need to run additional wiring."
"
The accessory control I/O use active low inputs. When the inputs are floating (nothing connected) the associated
output will be set to a high level. When the input is set to 0Volts (Ground) the input will activate its associated
output. All Accessory outputs are Open Collector type and will switch to Ground when activated."
"
Each input will have an associated output. See the following pages for a diagram of each I/O pair."
Inputs can be tested by making a jumper connection to ground and monitoring the associated output.
Input
Output
"
"
Suprex Operation and Initial Setup
"
I/O Controls
"
"
"
"
"
"
"
"
"
"
"
"
"
2-8 to 16 VDC In"
"
1-Ground
"
"
"
"
8-485(+)"
"
"
7-485(-)
6-+5 VDC Out"
"
5-Prog Res 2"
"
*
4-Prog Res 1"
"
3-LED Input"
"
2-D1/Data/F2F Out "
1-D0/Clock Out"
"
1-D0/CLK Output
"
"
"
"
"
"
"
"
"
2-8 to 16 VDC In"
"
1-Ground
"
"
"
8-485(+)"
"
"
7-485(-)
"
6-+5 VDC Out"
"
5-RLY4 Input (5V)"
*
"
4-RLY3 Input (5V)"
3-LED Output"
"
2-D1/Data/F2F Input"
"
1-D0/CLK Input
"
"
"
"
LED Input and Output
"
Central Unit
Red arrow denotes direction!
of command signal
Remote Unit
12-RLY4 N.O."
11-RLY4 Com"
10-RLY4 N.C."
9-RLY3 N.O."
8-RLY3 Com"
7-RLY3 N.C."
6-RS232 Out"
5-RS232 In"
4-Ground"
3-Aux Out"
2-Relay2 Input"
1-Relay1 Input"
12-RLY2 N.O."
11-RLY2 Com"
10-RLY2 N.C."
9-RLY1 N.O."
8-RLY1 Com"
7-RLY1 N.C."
6-RS232 Out"
5-RS232 In"
4-Ground"
3-Aux In"
2-N/C"
1-N/C"