- ページ 17
GPS ACR Electronics 406 PLBのPDF 製品サポートマニュアルをオンラインで閲覧またはダウンロードできます。ACR Electronics 406 PLB 20 ページ。 Personal locator beacon
3.2.4 Position data set to default:
GPS data will be set back to default once the beacon is turned OFF. During the self test burst,
default GPS data is transmitted even if GPS data is in memory.
4.0
MAINTENANCE
4.1
Carefully inspect the PLB case for any visible cracks. Cracks may admit moisture which could
falsely activate the beacon or otherwise cause a malfunction. Any cracking observed should
immediately be referred to ACR or nearest distributor for evaluation, (1-800-432-0227 Ext. 169)
toll free in the USA.
4.2
The battery must be replaced by the date indicated on the beacon. At each inspection, check the
time remaining until replacement is required.
NOTE: There are no user serviceable items inside the PLB. DO NOT OPEN THE PLB UNLESS
TO DISABLE IN CASE OF FAULTY ACTIVATION. Refer all long life battery replacement and
other internal PLB service to a factory authorized service center. For the nearest location of a
factory authorized service center, call 1-800-432-0227 Ext. 169 (toll free in the USA) or +1 (954)
981-3333, Ext. 169.
It is strongly recommended to test the PLB on a quarterly basis.
5.0
FREQUENTLY ASKED QUESTIONS
Q.
How do I download position data from my GPS to my beacon?
A.
You must have NMEA 0183 output ready GPS unit and a GPS interface cable. The NMEA
0183 optical interface connector supplied with your ACR beacon must be connected to the
EXTERNAL GPS I/R CABLE
FIGURE 8
14
Y1-03-0169 Rev. B