TROUBLESHOOTING

FAULT
CAUSE
Reduction or
Piston not being
loss of power
returned to the full
rear position
Worn or damaged
piston ring
Worn or broken
pawl
Tool does not
The firing pin
fire
and/or chamber
damaged
Tool is not being
fully depressed
Excessive dirt
build-up on
chamber face
Tool does not
Tool was
fully depress
assembled
incorrectly
Damaged parts
Debris jamming the
barrel or piston
assembly
Excessive
Power level too
fastener
high
penetration
Base material too
soft
Failure to index
Strip is damaged or
strip
not inserted in tool
properly
Indexing
mechanism
damaged
Tool cannot be
Damaged or bent
cocked or
piston
opened easily
Excessive dirt
build-up
Broken or damaged
parts
Failure of tool to
Retaining ball
stay closed when
missing
pointed in the
downward
position
POSSIBLE REMEDIES
Barrel must be pulled
completely open to
properly position the
piston
Replace worn or damaged
piston
Replace pawl
Replace the damaged part
See "Tool does not fully
depress"
After allowing misfire
procedure, check firing
pin indentation on load.
Clean chamber face.
Check all parts in the
receiver for damage or
improper assembly
Contact your distributor or
call the offices of Blue
Point Fasteners
Disassemble and remove
debris
Use a lower charge level.
Check the base material
and make sure it's not too
weak
Check load strip. If
damaged, dispose it off
appropriately
Contact Blue Point for
assistance.
Replace piston
Clean tool properly
Tag tool with warning :
"Defective-Do Not Use".
Place in a locked box and
contact your Blue Point
representative for service
Contact Blue Point for
assistance
20
TROUBLESHOOTING
FAULT
CAUSE
Piston Stuck in
Piston overdriven
down position
and stuck in muzzle
bushing
Load strip gets
Load stuck in the
stuck
chamber
Pin(s) stuck in
Pin inserted too far
fastener guide
POSSIBLE REMEDIES
Wear eye protection. Make
sure tool is unloaded, tap
on hard surface or drive
piston back with a lead or
brass hammer
Never try to remove an
unfired, live load from the
chamber. Call Blue Point
for assistance
Unscrew fastener guide,
remove buffer and push
the pin out with a
screwdriver