The usage of the calibration signal pin is optional. The pin (TTL, 5V) can be connected to a
microcontroller if user want to use it. The Calibration signal pin has the same functions as the
Cal button. Instead of manually pushing the Cal button for the settings of LSS05, user can
use a microcontroller to pull down the signal to get into the settings. It is similar to the Cal
button, pulling down signal pin once set the sensor bar into calibration mode, pulling down
the signal pin twice consecutively to set the sensor into dark line mode and pulling down the
signal pin 3 times consecutively set the sensor into bright line mode. The timing requirement
for the consecutive signals is 1.5 seconds (refer to the timing diagram).
Pin 8 which is Cal signal pin is connected to push button. Then the push button is connect to
microcontroller through a transistor.
Reminder: Please keep the Cal. signal at high logic level 5V if it's not generating pulse
for the function of the signal.