Warning: Turn OFF the power witch when installing lamp.
1. Loosen the four (4) hexagon socket head cap bolts by using the attached
hexagon wrench and take the front frame off from lamp housing.
2. Turn the anode female collet counterclockwise to loosen the anode male
collet.
3. Take the xenon lamp out of the case. Hold the cathode side (-) before you
and insert the anode side (+) into the anode male collet securely.
4. Turn the female collet clockwise to tighten the lamp.
5. Insert the receptacle into the tab terminal securely.
6. Install the front frame with four (4) bolts.
Caution: If you handle the xenon lamp with dirty hands, wipe off the stain on the
glass with alcohol.
10
Y1-03-0139 Rev. C