AMC iComC 2x20 사용자 설명서 - 페이지 8
{카테고리_이름} AMC iComC 2x20에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. AMC iComC 2x20 9 페이지. Communication amplifier
AMC iComC 2x20에 대해서도 마찬가지입니다: 사용자 설명서 (12 페이지)
Control protocol
RS 232 protocol
Baud rate of 9600
8 data bits
no parity
1 stop bit
no flow control
Notes:
Amplifiers respond prompt: PA>
Symbols xx in the volume control row mean volume level. Volume level range
is 0-63.
Example: RS232 command "Volume 15<CR>" sets volume level 15.
Symbol x in the "Source selector" row mean input number.
Example: RS232 command "Source 2<CR>" enables audio signal from input 2.
Symbol xx in the treble row mean treble level. Treble level range is from -7 to
+7. Default treble level is 0.
Example: RS232 command "Treble +3<CR>" sets treble level +3.
Example: RS232 command "Treble 0<CR> sets treble level to default.
Symbol xx in the bass row mean bass level. Bass level range is from -7 to +7.
Default bass level is 0.
Example: RS232 command "Bass +4<CR>" sets bass level +4.
Example: RS232 command "Bass 0<CR> sets bass level to default.
06
USER MANUAL
iComC 2X20 Communication Amplifier
Symbol xx in the balance row mean balance level. Balance level range is from L9
to R9. Default level is 0.
Example: RS232 command "Balance L5<CR>" sets balance to L5.
Example: RS232 command "Balance 0<CR> sets balance level to default.
Function
Show status
Power on
Power off
Power on/off
Mute on
Mute off
Mute on/off
Volume control
Source selector
Treble control
Bass control
Balance control
Save settings
Command
Now<CR>
Power On<CR>
Power Off<CR>
Power Toggle <CR>
Mute On<CR>
Mute Off<CR>
Mute Toggle<CR>
Volume xx<CR>
Source x<CR>
Treble xx<CR>
Bass xx <CR>
Balance xx<CR>
Save<CR>