{카테고리_이름} AMC SRL400/R에 대한 설치 관리자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AMC SRL400/R 6 페이지. Two-way radio buzzer kit for r400 series control units
DESCRIPTION OF THE ELECTRONIC BOARD OF THE BUZZER
antenna bush
anti-opening tamper
red LED
green LED
dip-switch funcions
The buzzer shell features a group of dip-switches with which the operator can select the following signals:
Can be enabled INDIVIDUALLY by BRINING the corresponding Dip-switch TO ON:
- Sound alarm log (DIP 1 ON);
emits a melody when the system is deacrivated following an alarm
- Visual alarm log (DIP 2 ON);
fast steady flashes after an alarm with the system enabled (goes off when the system is disabled)
- System ENABLED/DISABLED status sound signal (DIP 3 ON);
emits 3 BEEPS when the system is enabled and 1 prolonged beep when the system is disabled
- System ENABLED/DISABLED status visual signal (DIP 4 ON);
emits 3 brief flashes when the system is enabled and 1 prolonged flash when the system is disabled
- steady system ENABLED signal (DIP 5 ON);
when the system is enabled, a double flash is emitted
- Buzzer OK "stand-by" signal (DIP 6 ON):
emits a brief flash every 10 seconds, when the buzzer is working properly
www.amcelettronica.com
programming key
power supply
battery connector
blinker
SRL400/R V1.0 EN