Amcor AC12 사용자 설명서 - 페이지 10
{카테고리_이름} Amcor AC12에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Amcor AC12 12 페이지. Portable air conditioner
Amcor AC12에 대해서도 마찬가지입니다: 사용자 설명서 (13 페이지)
TROUBLE SHOOTING
Do not repair or disassemble the unit by yourself, unauthorized repair attempts will
invalidate the warranty and may cause bodily harm.
Trouble
Reason
No power supply.
The unit
Water-full indicator illuminated.
does not
Timer function is active.
work
Room temperature too low or too high. Use only in ambient temperatures between 7-40℃.
In direct sunlight.
Windows or doors open.
Large amount of people or a heat
The unit
source in the room.
does not
Filter is very dirty.
seem to
Air inlet or air outlet is blocked
perform.
Room temperature is lower than setting
temperature.
The unit loud The unit is not on a flat surface.
Compressor
does not
Overheating protection is active.
work
Operating distance is too far.
Remote
Control panel has not received the
control
signal from remote control.
doesn't work
The batteries are flat.
E1 on LED
Room temperature sensor is abnormal.
E2 on LED
Coil temperature sensor is abnormal.
Water tank is full inside the machine
Anti-freezing protection.
OTHERS
No refrigerant or there is very little
refrigerant.
High pressure protection.
If the above solutions do not resolve the problem please contact the service centre.
Solution
Power-on and turn on the unit.
Drain the internal water tank.
Cancel Timer function.
Draw the curtains, UV affects RC.
Close windows and turn on another air conditioner.
Clean or change the air filter
Clear out debris.
Change the setting temperature.
Put the unit on flat and hard surface.
check venting.
Restart the unit after 5 minutes when compressor has
cooled.
Move remote control closer to the unit and make
sure it aims at the air-outlet grille.
Replace the batteries
Temperature not within 5-40℃ operating range. If
temperature within operating range refer to Service
Centre.
(check room temperature sensor or relevant circuit)
Refer to Service Centre.
(check coil temperature sensor or relevant circuit)
Drain out water from drain port at bottom rear of
the unit.
Waiting for defrosting.
Function will recover automatically. No user input
needed.
Refer to Service Centre. (check leakage, wielding,
vacuum pump, charge refrigerant according to name
plate)
After inside gas pressure comes down, it will function
normally. No user input needed.
9