Birchdale Cast Iron 0715 07/07/2015 16:35 Page 6
This appliance is equipped with a pre-fitted manufacturers smoke
exempt stop. Under no circumstances should it be tampered with or
removed unless expressly authorised by a competent person and the
appliance is not installed in a smoke exempt area.
If the appliance is to be installed in a non smoke exempt area you can
remove the restricting screw on the secondary air control (indicated by
the two holes) to allow full movement of the secondary air slider.
The appliance is supplied pre-assembled with the flue spigot in the top exit
position.
If you intend to install the appliance using a rear flue connection, the blanking
plate should be swapped over as follows:
• Remove the internal baffle plate
• Remove the rear metal plate from the
back of the stove

Assembly of the unit

• Remove the rear blanking plate
• Remove the flue spigot from the top
exit by removing the securing bolts
and rope seal
• Refit the rope seal and flue spigot to
the rear exit and secure with the bolts
• Refit the blanking plate to the top exit
using the rope seal and retaining bar