FLOJET 20465010 매뉴얼 - 페이지 3

{카테고리_이름} FLOJET 20465010에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. FLOJET 20465010 8 페이지. Bottled water system

FLOJET 20465010 매뉴얼
Select a cabinet large enough to accommodate the 5 gallon (19L) bottle and suction wand assembly. Place the
pump module on the floor of the cabinet with on/off switch and suction tube facing out toward the cabinet doors.
Position as close as possible to a
grounded electrical outlet and
place the five gallon bottle close to
the pump module without kinking the
suction hose.
Push clip up to lock
Insert float sensor switch plug/connector into pump
module "SWITCH" port.
The connections for the float and power supply
will require moderate force to insert fully. This
is a design feature that assures the connections
are held securely after initial installation. MAKE
SURE PLUG / CONNECTOR IS INSERTED ALL THE
WAY INTO THE CONNECTIONS. FAILURE TO
INSERT FULLY WILL LEAD TO POOR OPERATION
OR NO OPERATION.

PLUMBING INSTALLATION

PLUMBING
To install tube into
"OUT" port. Push
1/4" discharge
tubing all the way
into quick
connect port
(as far as it will go)
Insert suction hose port
fitting into pump module
"IN" port and slide locking
port clip in place.
Insert DC plug/connector into pump module "DC IN" port.
The connections for the float and power supply will require
moderate force to insert fully. This is a design feature
that assures the connections are held securely after initial
installation. MAKE SURE PLUG / CONNECTOR IS INSERTED
ALL THE WAY INTO THE CONNECTIONS. FAILURE TO
INSERT FULLY WILL LEAD TO POOR OPERATION OR NO
OPERATION.
The Bottled Water Dispensing System may
also be placed in a pantry, closet, cellar or
other location where a grounded electrical
outlet is available.
To remove tube from "OUT" port:
1.
2.
3.
Push tube all the way in
Hold gray ring against black
port with finger or flat tool
Pull tube out
3