System Will Not Dispense Water
Check on/off switch position
Check power to dispensing system
Check location of suction wand in bottle
Check for empty bottle
Check for air in system
Discharge Tube Leaks At Fitting
Push tube all the way into tube stop
Remove tube and cut 1/4 in. (6.35 mm) off
end, square and reinstall
Check correct tube size in fitting, tube size
is 1/4 in. (6.35 mm) O.D. Fitting 1/4 in. (6.35
mm) I.D.
System Gets warm and turns off
Check the float switch
Check for leaks in discharge tube
Thermal protection feature is activated due
to excessive run time. This system is not for
continuous duty applications
Flojet warrants this product to be free of defects in material and/or workmanship for a period of one (1)
year after purchase by the customer from Flojet. During this one (1) year warranty period, Flojet will, at
its option and at no charge to the customer, repair or replace this product if found defective in material
or workmanship, with a new or reconditioned product. But not to include costs of removal or installation.
This is only an overview of our limited warranty. If you would like a copy of our warranty, please call or write
Flojet.
Prior to returning any product to Flojet, call +1 949 608 3900 customer service for an authorization number.
This number must be written on the outside of the shipping package. Place a note inside the package with
an explanation regarding the reason for return as well as the authorization number (include your name,
address and phone number).
8

TROUBLESHOOTING

Flojet
17942 Cowan
Irvine, CA 92614
Tel: +1 949 608 3900
Fax: +1 949 608 3887
www.xylemflowcontrol.com

RETURN PROCEDURE

System Will Not Shut-Off
Check for leaks in tubing system
Check for leaks at tube fittings
Check for leaks at faucet, ice maker or
refrigerator water valve
Check pressure switch by turning faucet off
and on
Check float switch position in bottle
System Continually Turns Off and On While
in Use
Check for restriction device at appliance
inlet.
Check for filter unit in line, remove if
present.
Check for internal filters in the refrigerator,
remove if present.