Malvern manual MAL2CLASSIC 0916-1 28/10/2016 11:45 Page 9
Re-fueling
When refueling the stove always refuel
onto a bed of hot embers, fully open
the secondary and primary air controls
until the new fuel is well alight, before
adjusting the air controls for the desired
setting.
If there is insufficient burning material in
the firebed to light a new fuel charge,
excessive smoke emission can occur.
Refuelling must be carried out onto a
sufficient quantity of glowing embers
and ash that the new fuel charge will
ignite in a reasonable period. If there are
too few embers in the fire bed, add
suitable kindling to prevent excessive
smoke.
Operation with door left open
Operation with the door open can cause
excess smoke. The appliance must not
be operated with the appliance door left
open except as directed in the
instructions.
Air controls left open
Operation with the air controls or
appliance dampers open fully can cause
damage to the appliance. The appliance
must not be operated with air controls,
appliance dampers or door left open
except as directed in the instructions.
• Never leave the stove unattended
until the new fuel is well alight.
• Persistent fume emission is
dangerous and must be
investigated.
Operating your stove
Fuel overloading
Never overload the stove - it will work
very well with two medium sized logs.
The amount of fuel specified in this
manual should not be exceeded,
overloading can cause excess smoke.
Daily Maintenance
The ashpan should be checked and
emptied regularly.
• You should never allow the ashes in
the pan to build up to the level of
the grate.
If they are allowed to build up, the grate
will become sandwiched between the
ash below it and above it. This will
overheat the grate and cause distortion
and premature wear.
If fume emission persists, open doors
and windows to ventilate the room and
let the fire die. Have the chimney
inspected for blockages and clean if
required. Do not relight the fire until the
cause has been found. We recommend
that you seek professional advice.
This appliance has been designed to
be burned with the door closed at all
times other than when refueling.
It should not be operated as an open
fire.
Typical refueling intervals for wood is
1 hour and smokeless fuel is 2 hours.