AME 15924 사용 설명서 및 부품 분석 - 페이지 4
{카테고리_이름} AME 15924에 대한 사용 설명서 및 부품 분석을 온라인으로 검색하거나 PDF를 다운로드하세요. AME 15924 4 페이지. 5 quart air/hydraulic pump, steel reservoir
AME 15924에 대해서도 마찬가지입니다: 사용 설명서 및 부품 분석 (6 페이지)
Symptom
Application will not extend, move
Application responds to
does not maintain pressure
pump (ie. Cylinder will not retract)
Application will not fully extend
(cylinder or spreader)
Poor Performance
AME INTERNATIONAL
AME INTERNATIONAL
AME INTERNATIONAL
INSTRUCTION MANUAL
15924 INSTRUCTION MANUAL & PART LIST
& PARTS BREAKDOWN
5QT. AIR PUMP W/ STEEL RESERVOIR
TROUBLE SHOOTING
Possible Causes
• Overload Condition
•
Overload condition
• Release Valve not closed
•
Release valve not closed
• Overload Condition
•
Overload condition
• Release Valve not closed
•
Release valve not closed
• Hydraulic unit malfunction
•
Hydraulic unit malfunction
• Malfunctioning coupler,
•
Malfunctioning coupler,
damaging application
damaged application
•
Reservoir overfilled
• Fluid level low
•
Fluid level low
•
Fluid level low
• Fluid level low
• Air trapped in System
•
Air trapped in system
2324 Circuit Way, Brooksville, Fl 34604
(877)775-4263 • www.ameintl.net
2347 Circuit Way, Brooksville, Florida, USA 34604
Phone: (+1) 352-799-1111
- 6 -
- 6 -
Fax: (+1) 352-799-1112
Corrective Action
• Remedy overload Condition
•
Remedy overload condition
• Ensure release valve closed
•
Ensure release valve closed
• Remedy overload Condition
•
Remedy overload condition
• Ensure release valve closed
•
Ensure release valve closed
• Secure load by other means. Open
•
Secure load by other means. Open
release valve, depressurize pump
release valve, depressurize pump and
and hose, remove coupler and/or
hose, remove coupler and/or
application, then do not replace.
application, then will not return replace
•
Secure load by other means. Open
• Secure load by other means. Open
release valve, depressurize pump and
release valve, depressurize pump and
hose, remove application, then drain to
proper fluid level.
hose, remove application, then drain
• Follow Symptom 3 procedure for
•
Follow Symptom 3 procedure for
securing load, depressurizing pump,
securing load, depressurizing pump,
remove application, then ensure proper
remove application, then ensure
fluid level.
•
Ensure proper fluid level
•
Ensure vented oil filler plug lets
pressurized reservoir air escape
pressurized reservoir air escape
(see before use)
(see before use)
5
Toll Phone: (+1) 877-775-4AME (4263)
E-mail: [email protected]
WWW.AMEINTL.NET
WWW.AMEINTL.NET
www.ameintl.net