Coastal Amusements TOY SOLDIER 운영 매뉴얼 - 페이지 12
{카테고리_이름} Coastal Amusements TOY SOLDIER에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Coastal Amusements TOY SOLDIER 16 페이지.
Coastal Amusements TOY SOLDIER에 대해서도 마찬가지입니다: 운영 매뉴얼 (16 페이지)
TROUBLESHOOTING
1. Take caution with the positive and negative poles of the DC power (+5V, +12V, +24V, +48V) in this
machine when repairing it. Connect the poles correctly in order to avoid burning the PCB and/or
operation under abnormal condition.
2. Coins/tokens can not be inserted into coin slot:
(1) Check if anything is stuck in the coin slot
(2) Check if coin slot is dis-formed or intentionally damaged
(3) Check if the coin selector is of correct specification
3. Coins/tokens are returned after coin in:
(1) Check if coins/tokens are of correct specification
(2) Check if connecting pin is properly connected (only in electronic coin selector)
(3) Check if coin selector is of correct specification
4. No credit after coin in:
(1) Check if sliding end of coin selector is properly matched the Y-type funnel
(2) Check if coin SW is properly positioned to end of Y-type funnel
(3) Check if coins/tokens properly touch the coin SW after coin in
5. Claws does not lower down:
(1) The winding cord is improperly wound up. Hold stop-up SW (Gantry & Assembly II No. 29) and
power off then power on again. The winding cord should be properly wound up now.
(2) Check if winding cord is out of the track. If so, wind the cord properly back to track and power
on. The claws should go back to its normal function.
Note: unscrew and dissemble the top and front covers of gantry motor to check the winding
cord.
(3) Shaking the machine beyond the normal limits during playing could cause to this
mal-functioning.
6. When displays show『C0』blinking, coin selector is at improper position N.C. (normal position is
N.O.), possible conditions could be:
(1)
If『C0』keeps blinking after holding coin SW and re-power on, it is then at condition for
adjusting claws strength. Pls. refer to Claws 'Strength Instructions'.
(2) 『C0』will also blink during the operation when coin SW is stuck or out of position causing it
unable to detect whether it is or it's not already coin in. Adjust the coin SW back to its proper
position.
- 11 -