Aktakom AMM-1081 운영 매뉴얼 - 페이지 7
{카테고리_이름} Aktakom AMM-1081에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aktakom AMM-1081 20 페이지. Smart multimeter
DC/AC Current
Range
Resolution
Accuracy
Over load
protection
Remark
OHMS
Range
Resolution
Accuracy
Over load protection
Capacitance
Range
Resolution
Accuracy
Remark
Frequency
Range
Resolution
Accuracy
Input impedance
Over load protection
* auto range
mA range
10 A range
mA range
10 A range
mA range
10 A range
mA range
10 A range
* ACA specification be tested on
sine wave 50/60 Hz.
* For smart function ,the ACA start
measurement is
10 A range : 1.50 A.
mA range : 1.50 mA.
* auto range
600/6 K/60 K/600 K/6 M ohm
0.1/1/10/100/1 K ohm
± ( 1% + 3d )
± 350 DCV, 350 ACV
* auto range
6 nF/60 nF/600 nF/6 uF/60 uF
0.001 nF/0.01 nF/0.1 nF/0.001 uF/
0.01 uF
± ( 3% + 5d )
Discharge capacitor before testing.
40 Hz to 1 KHz.
1 Hz.
± ( 0.3% + 2d )
10 M ohm.
AC/DC 600 V.
4
www.tmatlantic.com
600 mA/60 mA
10A
0.1 mA/0.01 mA
0.01 A
± ( 1.2% + 2d )
± ( 1.5% + 2d )
630 mA fuse
10 A fuse