2. Installation

Reasonable installation is critical factor of the instrument's normal working.

2.1 Installation considerations

2.1.1 general hints
 Installation must be carried out by trained person in accordance with the
manual.
 The temperature of the process may not exceed 60℃,and the pressure
may not exceed ±0.1 MPa.
 The use of metallic fittings or flanges is not recommended.
 For exposed or sunny locations a protective hood is recommended.
 Make sure the distance between the probe and the maximum level
exceeds the blacking distance, because the probe cannot detect any
liquid or solid surface closer than the blacking distance to the probe's
face.
 Install the instrument at right angles to the surface of the measuring
material.
 Obstructions within the beam angle generate strong false echoes.
Wherever possible, the transmitter should be positioned to avoid false
echoes.
 The beam angle is 8°, in order to avoid large echo loss and false echo,
the probe should not be mounted closer than 1 m to the wall. it is
advisable to maintain a distance of at least 0.6m from the center line of
the probe for every foot (10cm per meter) range to the obstruction.
2.1.2 hints for liquid surface conditions
 Foaming liquids can reduce the size of the returned echo because foam
is a poor ultrasonic reflector. Mount an ultrasonic transmitter over an
area of clear liquid, such as near the inlet to a tank or well. In extreme
conditions, or where this is not possible, the transmitter may be
mounted in a vented stilling tube provided that the inside
measurement of the stilling tube is at least 4 in. (100 mm) and is
smooth and free from joints or protrusions. It is important that the
bottom of the stilling tube stays covered to prevent the ingress of
foams.
 Avoid mounting the probe directly over any inlet stream.
 Liquid surface turbulence is not normally a problem unless it is excessive.
The effects of turbulence are minor, but excessive turbulence can be
www..aktek.com.tr