GPI settings

Here the default GPI settings can be adjusted. For GPI only, the TCP commands are not used.
For an Axia node the GPI or GPO can be selected with the corresponding pin where the color RED
will be activated. GPI1 – 8, GPO1 – 8 and Pin 1-5.
For an Axia QOR the name of the fader channel needs to be entered in the TCP 1 field. For example
Mic-DJ or Mic 1. The name entered here has to correspond exactly to the name used in the QOR
and is case sensitive.
On change of a show profile on the Axia desk from example fader 1 to fader 3 the MOS-UNO-IP
will follow the change.
On first installation or reboot of the MOS-UNO-IP a show profile has to be loaded to let the MOS-
UNO-IP know the corresponding fader channel.
GPIO, Pin and TCP off settings are not used when the QOR has been selected.
On choosing listen to server the MOS-UNO-IP will only listen on TCP port93 to commands
directly send to the IP address of the MOS-UNO-IP. To activate or deactivate the red light, the send
command has to exactly match the commands in TCP on and TCP off. These commands are case
sensitive.
The MOS-UNO-IP uses standard ASCII charracters for the TCP commands. To test a command a
simple freeware program like packet sender can be used.
On the use of DHD global logics the name of TCP on and off will change After saving settings.