Euro-Clear BlueSoft 1354EA-RX 메카닉 매뉴얼 - 페이지 13

{카테고리_이름} Euro-Clear BlueSoft 1354EA-RX에 대한 메카닉 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Euro-Clear BlueSoft 1354EA-RX 15 페이지. Iron, manganese, ammonia and other natural organic matter removers, water softeners with ecomix media

Water purification and treatment equipment manufacturer and wholesale distributor
Tel: +36 96 544-240 • Fax: +36 96 544-248 • E-mail: [email protected] • Web: www. euro-clear.eu
Data sheet for setting up
1. Check the mechanical and electricity connections as follows:
1.1.
Is a mechanical protection filter built in front of the device?
1.2.
Is the pressure of the raw water convenient? (2,5 – 6 bars)
1.3.
Are the directions of water flow convenient? (on the montage block, on the device) 
1.4.
Is the rinsing water outlet of the device connected into the channel?
1.5.
Is the electricity input right? (230V, 50HZ)
2.Program the control head of the filtrating device
2.1.
Have the exact date and time been set?
2.2.
Setting the time for regeneration
2.2 1.
In case the device is time controlled, has the time between the two washings been
set up?
If yes, it is
2.3.
Setting washing times (advanced settings)
2.3.1.
Backwash (Backwash)
2.3.2.
Rinse
3.Starting manual wash, checking operation cycles:
3.1.
Backwash (water comes intensively into the channel).
Is everything all right with the operation cycle?
After washing, is the water that comes out into the channel clean?
3.2.
Post washing (bigger volume water into the channel)
After washing, is the water that comes out into the channel clean?
3.3.
Repeat points 3.1. and 3.2. several times in a row as long as the outcoming water into
the channel gets clear.
Has the charge got clean?
How often did you have to repeat points 3.1. and 3.2. ?
4. After regenerating, check the iron and manganese content of the water that comes out from the device.
Iron content:
Manganese content:
In case the iron content of the water gets checked in laboratory, attach the copy of the measurement
report.
5. Train the staff that handle the device.
6. Filling in the warranty document
7.
Sending back the data sheet of setting up filled in and signed (terms of warranty) to the address
below.
BlueSoft Industrial Iron and Manganese Remover
Euro-Clear Kft.
Has the time been set up?
(Rinse)
Has the time been set up?
Yes
......days
............
...........mg/l
...........mg/l
Page 13.