Air Boss 824256VAT 매뉴얼 - 페이지 8
{카테고리_이름} Air Boss 824256VAT에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Air Boss 824256VAT 15 페이지.
WARNING
ALL ELECTRICAL WIRING SHOULD BE DONE
BY A QUALIFIED ELECTRICIAN
General Information
Adequate wiring and motor protection
should be provided for all stationary
compressors. Wiring used for other
machinery should not be used. A
qualified electrician familiar with local
electrical codes in your area should be
used.
WARNING
To reduce the risk of electrical hazards, fire
hazards or damage to the compressor, use
proper circuit protection. Your compressor
is wired at the factory for operation using
the voltage shown. Connect the compressor
to a power source with the correct breaker
size.
WARNING
Electrical connections must be properly
grounded. Ground connections should be
connected at the grounding screw.
CAUTION
Overheating, short circuiting and fire damage
will result from inadequate wiring.
STARTING THE COMPRESSOR
STARTING THE COMPRESSOR
Prior to actually running the compressor,
check the following items:
Crankcase oil - Make sure the sight glass
shows ½ full or slightly above.
Make sure all rags, tools, oil, etc. are away
from the unit.
Open the air system to free it of any pressure.
Switch the compressor on for a few
revolutions to make sure the rotation is
correct. Correct rotation is clockwise
when facing the sight glass on the pump.
WIRING
WIRING
824252PAT
824253PAT
Model
824256VAT
Voltage
115V / 1 ph
FLA
15
20 amp
Breaker Size
The motor is equipped with a manual,
resetable overload device to protect it from
overheating. In the event the compressor will
not run and power is properly connected and
on, press the motor overload reset button
located on the non drive end of the motor.
Operate the compressor for a few minutes
unloaded (air system open) then allow the
compressor to pump up. Make sure the
electrical pressure switch properly switches
off the compressor according to the setting
desired.
CAUTION
Make sure the pressure in the tank does
not exceed its rating. Single stage comp-
ressors should operate at a maximum of
135 psi. If the pressure gauge indicates
a pressure thatis higher than these
maximum pressures, shut off compressor
immediately and call 1-866-869-3114.
Page 6
Incoming power
should be connected
to the posts
marked (LINE)
Do Not Make
Connections On
Prewired Posts
Marked (MOTOR)!
Electrical connections
must be properly
grounded. Ground
connections should be
82476VAT
connected at a
grounding screw.
208-230V / 1 ph
16
30 amp