American Standard Seva 1480.500 설치 지침 - 페이지 2

{카테고리_이름} American Standard Seva 1480.500에 대한 설치 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. American Standard Seva 1480.500 2 페이지. American standard pressure balanced bath and shower fittings installation instructions

American Standard Seva 1480.500 설치 지침
1
Turn off water at MAIN supply. To prevent damage temporarily
CAUTION
remove STOPS when water supply lines are soldered to the manifold.
NOTE
When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK STOPS (IF PRESENT). When
finished soldering, flush valve body, replace cartridges, check stops (if present) and plaster guard
to continue installation. Use thread sealant or Teflon tape on threaded connections
ROUGHING-IN
See Roughing-in diagram on reverse side.
Connect RISER PIPE to MANIFOLD top outlet marked "SHR".
Connect TUB FILLER PIPE at bottom outlet marked "TUB".
Supply connections are:
1/2" copper sweat for sweat inlets.
1/2" female NPT for threaded inlets.
For proper positioning the finished wall must be within side wall of
If the valve is installed on a fiberglass or other thin wall application, the PLASTER GUARD can
be used as a support:
Cut a 3" dia. hole in the shower stall.
If stops are used drill two additional 1" holes to allow access to the stops.
Remove PLASTER GUARD, rotate 180˚ so that indicated screw holes fit manifold.
Push CAP on valve, place ESCUTCHEON and attach with screws.
Connect hot and cold water supplies.
For support, use pipe BRACES secured to wooden braces.
With valve turned off, turn on water supplies and check for leaks.
2
INSTALL TRIM
When finished, tiling the wall, remove PLASTER GUARD.
Push on CAP.
Mount ESCUTCHEON with SCREWS.
Install HANDLE by pushing it onto
CARTRIDGE STEM and tightening
SET SCREW from below.
Install SHOWER ARM with FLANGE and SHOWER HEAD.
Install SPOUT.
Check proper operation of HANDLE
and DIVERTER SPOUT.
3
HOT LIMIT STOP
By restricting handle rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To set the maximum
hot water temperature of your SEVA faucets, all you need
to do adjust the setting on the HOT LIMIT SAFETY STOP.
Remove HANDLE, CAP and HOT LIMIT STOP. Follow "A" or "B"
to adjust maximum discharge temperature.
"A"
PRY FORWARD TO UNLOCK
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
ADJUSTMENT WHEN
WATER IS TOO HOT
PLASTER GUARD.
"B"
PRY FORWARD TO UNLOCK
AND ROTATE CLOCKWISE
ADJUSTMENT WHEN
WATER IS TOO COLD
BRACE (4) *
RISER
PIPE *
BODY
HOT
PLUG
(NPT)
PLUG
(SWEAT)
TUB FILLER TUBES*
(5/8" O.D. -
1/2"
NOMINAL)
REMOVE BURRS
FROM TUBE
* NOT INCLUDED
IN KIT
CARTRIDGE
STEM
ESCUTCHEON
SCREWS
ESCUTCHEON
4
SERVICE
If faucet drips, operate handle several times from "off" to "on".
Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow in "full
on" hot or cold. To clean inlets, first turn off water supply,
then:
Remove HANDLE, CAP, HOT LIMIT STOP and CARTRIDGE.
Clean inlets and MANIFOLD.
Reassemble CARTRIDGE, alternately tightening screws. Replace
HOT LIMIT STOP , CAP and HANDLE. Check flow.
VALVE
BODY
MANIFOLD
CARTRIDGE
SEALS
FLANGE
SHOWER
HEAD
SHOWER
ARM
COLD
CARTRIDGE
SCREWS
STEM
PLASTER
GUARD
SPOUT
CAP
HANDLE
BUSHING
METAL
LEVER
HANDLE
SET
SCREW
CARTRIDGE
CARTRIDGE
MTG. SCREWS
HOT LIMIT
STOP
M968395 Rev. 1.1