Domus Ventilation HRXE-AURA-H 설치 지침 매뉴얼 - 페이지 5
{카테고리_이름} Domus Ventilation HRXE-AURA-H에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Domus Ventilation HRXE-AURA-H 12 페이지.
3.7.1 Pre Commissioning HRXe-AURA mvHR Units
HRXe-AURA units are designed to ventilate the whole dwelling
and must not be used during site construction or the clean-up
period. Cement and plaster dust can be abrasive and can affect fan
performance and reliability. Please ensure that the filters are checked
prior to commissioning to ensure there is no build-up of dust or debris.
While the property is drying out, very high moisture levels are likely
to occur. Therefore it is advisable that if the installation and building
works are complete the unit is left running. If the building works are not
complete please close the air valves or cover up the air valves to prevent
condensation forming in the ductwork and the HRXe-AURA unit due to
natural migration of warm air.
3.8 Dimensions
9
671951 | NovembeR 2020
Front View
Magnetic
Filter Covers
657
Top View
458
Unit Dimensions
Side View
Mounting Bracket
(Not to be used when
unit is fitted with
HRXE-AURA-AV Tray)
18.5
431
4x Ø150
Spigots
PAGe 5