ACS 775SL-SP Installation and Operations
Manual Interface Schematic
n
Connector Pin-out
The ACS 775SL-SP wiring harness should be constructed of Tefzel aircraft wire (M22759/16 grade
or better). Power and ground wires should be 18 or 20 AWG, and all other wires may be 22 AWG.
Shielded wires should be used where noted. Adequate protection against wear and chafing should be
taken by using a braided cable sleeving or jacket. Before completing installation, verify that all cable
connector pins are seated properly and that the connector is securely mounted to the unit mating
connector. Important - please note the power of the unit before installing; it will be either 14VDC or
28VDC and clearly marked as such on the units data tag.
Pre-fabricated cable harnesses are available from Air Comm to expedite installation - consult our
sales department for details.
Air Comm Systems, Inc.