FLUSH VALVE ASSEMBLY
P/N: 7381557-400.0070A
TO RE-INSTALL:
• Install the valve, orient valve assembly so
overflow funnel is positioned towards the
back of the tank (see FIGURE 4)
• Hold the valve in the tank with one hand
• Place friction washer over threads on bottom
of the tank (see FIGURE 5)
• Attach nut; orientation tabs must face away
from tank (see FIGURE 6)
• Use supplied tool to tighten nuts to tank
bottom, at least one hand tight
• Apply and work gaskets around the 6
retaining tabs on the nut so the inner rib on
the gasket is captured between the tabs and
the tank. Note the inner rib on the gasket is
offset to one side. Be sure to orient the
gasket with the inner rib towards the bottom
of the tank. When done correctly, the gasket
should not be compressed and should be
held in place while installing the tank.
• Re-mount tank to bowl (see FIGURE 1)
• Re-attach the refill tube into the overflow
funnel connection of the new valve
• Insert the BLACK trip lever arm in to the
chain coupler of the bead chain; push the
clevis pin through the arm and insert the hair
pin (see FIGURE 3)
• Insert the RED trip lever arm in to the yoke
of the teeter bar; push the clevis pin through
the arm and insert the hair pin (see FIGURE
3)
----------------------------------------------------------------
Product names listed herein are trademarks of AS America Inc.