LARGE COSMOPOLITAN
CONTROL
240V WIRING DIAGRAM
WITH OPTIONAL BUILT-IN

LOW VOLTAGE CONTROL

BLUE (COMMON)
BROWN (HOT)
240VAC 50HZ
GREEN
GROUND–MUST BE
CONNECTED TO
BUILDING GROUND
ILT RJ9 PIN-OUTS
(TAB IS FACING UP)
IR or UP
BLACK
GND COMMON
RED
+5V
GREEN
DN or DATA
WHITE
SCREEN AdjUSTMENT FOR 240v SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL
1. Remove the cover plate from the 3-button wall switch and remove the switch from the junction box.
2. Locate small 3-position switch on back of wall switch. see figure 4 for 120v screens or figure 5 for 220/240v
screens.
3. To adjust the down limit switch, slide the 3-position switch to the down position. Press and hold the down button
to run the screen down to the desired stop position. Release the button to stop the screen. do noT Push ThE
sToP BuTTon.
4. when the screen is in the desired down position, slide the 3-position switch to the off (center) position. The down
limit switch is now set.
5. To adjust the up limit switch, slide the 3-position switch to the up position. Press and hold the up button to run the
screen up to the desired stop position. Release the button to stop the screen. do noT Push ThE sToP
BuTTon.
6. when the screen is in the desired up position, slide the 3-position switch to the off (center) position. The up limit
switch is now set.
7. To test limit switch setting, make sure the 3-position switch is in the off (center) position. Press and release the up
or down button on the wall switch to operate the screen.
8. Replace switch and cover plate on the wall.
NOTE: if stop button is pressed, the wall switch will reverse direction. To correct this, press the stop button again. This
will reset the switch. You will have to re-set both the up and the down settings.
IMPORTANT NOTE: The wall switch is REQuiREd to make any limit switch adjustments, EvEn if a third party control
system is used. Therefore, it is advised to wire the switch or provide a 4-conductor connection that is
accessible.
®
ELECTROL
®
INSTALLATION FOR 240V SCREENS WITH A BUILT-IN LOW VOLTAGE
GREEN
GROUND TO CASE
IMPORTANT NOTE: The wall switch is REQuiREd to make any limit
OPTIONAL IR AND RF
REMOTE CONTROL
MOTOR
RJ9
SPLITTER
DRY CONTACTS
switch adjustments, EvEn if a third party control
system is used. Therefore, it is advised to wire
the switch or provide a 4-conductor connection
that is accessible.
5 5
CONNECT SUPPLIED
RJ9 CABLE TO
SPLITTER AND
SWITCH, OR USE 4
CABLE CONDUCTOR
TO CONNECT TO
LOW-VOLTAGE WALL SWITCH
SCREW TERMINALS.
UP
RJ9
STOP
DOWN
FRONT
FIGURE 5
UP DN
GND +5V
3-POSITION
RJ9
SWITCH
BACK