Troubleshooting

Symptom
Screen will not operate
and motor does not hum.
Incorrect stopping position in
downward direction.
Incorrect stopping position in
upward direction.
Noise.
NOTE: Screen will operate
with a low pitched hum.
Coasting.
Restoring Lost Roller Wrap
1.
Tape a strap to the bottom of the screen surface.
2. Push strap over back of roller.
3. Feed fabric as you pull strap to draw fabric over top of roller.
4. Remove tape and strap.
Cause
Incorrect line voltage.
Branch circuit fuse blown.
Tripped branch circuit breaker.
No power to operating switch or junction.
Power at junction box
Thermal overload tripped.
Broken wire in the "down" or "up" position.
Defective motor, limit switch or capacitor.
Motor capacitor burned out..
Lost roller wrap.
"Down" limit switch out of adjustment
Lost roller wrap.
"Up" limit switch out of adjustment
Gear Noise.
Defective brake.
Solution
Verify 115-125V (or 220-240V). If insufficient voltage, rewire
incoming electric line..
Replace fuse.
Reset circuit breaker.
Check above. Tighten all loose wire connections.
Correct any improper connections.
"Down" Position
Check for power across black and white leads.
"Up" Position
Check for power across red and white leads.
Let motor cool down for 15 minutes. Try again.
Check for continuity. Cut off old splice and reconnect.
Replace motor assembly. NOTE: Motor is a sealed assembly.
Replace motor assembly.
See instructions below..
See installation instructions.
See instructions below..
Adjust "up" limit switch. See installation instructions
Replace motor assembly.
Replace motor assembly.
7