DAAB DB409 사용 설명서 - 페이지 6
{카테고리_이름} DAAB DB409에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. DAAB DB409 12 페이지. Interface card for frequency converter vfd-el
Installing the Delta VFD-EL frequency converter
• Modification of the motor winder
The following criteria must be met in order to use the DAAB motor winder with the frequency converter:
• If mechanical limit switches are used, the limit switch cams must be wider than normal.
• FAAC Nordic AB recommends using encoder-type limit switches, DB405, together with the frequency converter.
• FAAC Nordic AB recommends using a motor with a speed of 2,800 rpm.
• Programming the frequency converter
To program the frequency converter, press ENTER once to select programming mode. Select program group 00.xx to 11.xx
using the arrow keys. Press ENTER to select program group. The program arrows now switch between the different program
channels in the selected program group. Press ENTER once more at the selected program channel and select value using the
arrow keys. When you have set the desired value, press ENTER again to save the new value. When all the programming has
been done, you return to normal operation by pressing MODE until the display shows H for the output frequency concerned.
Tip: By pressing MODE once more when stepping between the program channels, you change to stepping between the
program groups instead.
• Channel settings in the frequency converter
Channel
no.
00.03
used to display the output frequency during operation after power is
switched on
01.00
used to set the maximum output frequency
01.03
used to set the low frequency
01.04
used to set the low frequency voltage
01.05
used to set the start frequency
01.06
used to set the start frequency voltage
02.00
used to set where the setpoint value for speed is to be taken from
02.01
used to set the start method
02.02
used to set the type of stop
02.04
used to block reversing
03.00
used to set the multifunction output
03.08
used to set the internal cooling fan
04.04
used to set the function of input MI1
06.01
used to set the current limit for a speed increase
06.02
used to set the current limit at constant speed
06.06
used to set the electronic overload relay
09.00
selects communication address: 1 for motor 1, 2 for motor 2
09.01
used to set transfer speed
09.02
used to set error handling
09.07
used to set time delay between messages
6
6
Description
DAAB INTERFACE CARD DB409 INSTRUCTION MANUAL
Factory
Modified
setting
value
01
100.0
5.00
40.0
1.50
30.0
03
01
01
01
01
01
00
200
200
02
1
03
0
0
Revision 7