American Standard ACONT202AS11MA 설치 및 사용자 설명서 - 페이지 5
{카테고리_이름} American Standard ACONT202AS11MA에 대한 설치 및 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. American Standard ACONT202AS11MA 12 페이지.
4.5
Wiring Diagrams
Cooling with TAM7/TAM9 (24V Mode)
Thermostat
Rc
Rh
O/B
Y
G
W
C
Cooling with GAF2-S
Thermostat
Rc
Rh
O/B
Y
G
W
C
Pub. No.
11-HD20D1-1A-EN
Indoor Unit
R
O
Y1
G
W1
B
Y0
Indoor Unit
R
G
W1
B
12/2018
37-7778003
Part No.
American Standard 202 Programmable Thermostat
Outdoor Unit
NOTES:
1) Wire third party condensate over ow
switches between Y of the thermostat
and Y1 of the air ow control board
2) X2 is required to energize aux heat
during defrost
Outdoor Unit
NOTES:
1) Wire third party condensate over ow
switches between Y of the thermostat
and Y1 of the air ow control board
2) X2 is required to energize aux heat
during defrost
B
Y
Y
B
5