American Standard ACONT600AF11MA 설치 지침 매뉴얼 - 페이지 14

{카테고리_이름} American Standard ACONT600AF11MA에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. American Standard ACONT600AF11MA 15 페이지. Programmable comfort control

American Standard ACONT600AF11MA 설치 지침 매뉴얼
In case of difficulty
Heating equip-
ment is running
in cool mode
Cannot change
system setting
to "Heat"
Cannot change
system setting
to "Cool"
"Heat On" is not
displayed
"Cool On" is not
displayed
"Cool On" or
"Heat On"
is flashing
Accessories & replacement parts
Please contact your distributor to order replacement parts.
Battery holder ........................................................Part Number THT02506
Cover plate assembly ..........................................Part Number BAYCOVR700A
(Use to cover marks left by old thermostats.)

Specifications

Temperature Ranges
Heat: 40° to 90°F (4.5° to 32°C)
Cool: 60° to 99°F (16° to 37°C)
Operating Ambient Temperature
32° to 120°F (0° to 48.9°C)
Shipping Temperature
-20° to 120°F (-28.9° to 48.9°C)
Operating Relative Humidity
5% to 90% (non-condensing)
Physical Dimensions
3-9/16" H x 5-13/16" W x 1-1/2" D
91 mm H x 147 mm W x 38 mm D
Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed heating/cooling equipment (see page 7).
Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed heating equipment (see page 7).
Change Installer Setup, Function 12 (System Setting) to Manual or Auto
Changeover (see page 7).
Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed cooling equipment (see page 7).
Change Installer Setup, Function 12 (System Setting) to Manual or Auto
Changeover (see page 7).
Change the System Setting to Heat, and set the temperature level above
the current room temperature.
Change the System Setting to Cool, and set the temperature level below
the current room temperature.
Compressor protection timeout is engaged. Wait 5 minutes for the
system to restart safely, without damage to the compressor.
Electrical Ratings
Terminal
Voltage (50/60Hz) Running Current
W (O) Heating
Y Cooling
G Fan
12
20-30 VAC
20-30 VAC
20-30 VAC
0.02-1.0 A
0.02-1.0 A
0.02-0.5 A