American Standard 7293.252F15 설치 지침 - 페이지 2
{카테고리_이름} American Standard 7293.252F15에 대한 설치 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. American Standard 7293.252F15 3 페이지. Exposed wall mount sink faucet and gooseneck spout
2
FINISH INSTALLATION
Apply thread sealant or teflon tape to SUPPLY NIPPLES (1).
Slide COUPLING NUTS (2) onto INLET SHANKS (3).
Thread ESCUTCHEONS (4) fully onto INLET SHANKS (3).
Thread INLET SHANKS (3) onto SUPPLY NIPPLES (1). Distance
between INLET SHANK (3) outlets must be 8" to match the VALVE (5).
Insert RUBBER WASHERS (6) into INLET SHANK (3).
Attach VALVE (5) to INLET SHANKS (3).
Tighten both COUPLING NUTS (2) firmly.
3
TEST FAUCET
Remove AERATOR (1).
Turn HANDLES TO OFF POSITION.
Slowly turn water supplies on and check all connections for leaks.
Operate HANDLES to flush water lines thoroughly.
Turn HANDLES to OFF position and replace AERATOR (1).
Thread ESCUTCHEONS against finished wall.
4
SERVICE
To change direction of handle rotation, proceed as follows:
Turn HANDLE to OFF position.
Remove HANDLE SCREW and HANDLE.
Remove SPRING CLIP (1).
Lift STOP WASHER (2), turn 90° and replace.
Replace SPRING CLIP (1).
Replace HANDLE and HANDLE SCREW.
AERATOR may accumulate dirt causing distorted and reduced water flow.
Remove AERATOR and rinse clean.
If spout drips, operate handles several times from OFF to ON position.
Do not force - handles turn only 90°.
1
4
2
13/32"
3
6
1
2
8"
5
90°
1
M968264 REV. 1.5 (3/16)