American Standart SELECTRONIC 6057.193 설치 지침 매뉴얼 - 페이지 6

{카테고리_이름} American Standart SELECTRONIC 6057.193에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. American Standart SELECTRONIC 6057.193 11 페이지. Proximity infection control faucet

AC VERSION; Fig. 2
2
Before opening ENCLOSURE
CAUTION
disconnect AC power supply.
NOTE: For AC installation see Fig. 2b.
Make power supply connection before mounting
ENCLOSURE (1) to wall.
1. Remove ENCLOSURE COVER (1). Fig. 2.
2. Feed the EXTENSION CABLES (2) from the Faucet
through the top of ENCLOSURE (3). Fig. 2a.
3. Remove SPLIT PLUG (4) from POWER SUPPLY
GROMMET (5). Insert POWER CORD (7) into SPLIT
PLUG (4). Insert POWER CORD CONNECTOR (6)
through POWER SUPPLY GROMMET (5). Push SPLIT
PLUG (4) into POWER SUPPLY GROMMET (5) to seal.
Fig. 2b.
4. Insert POWER CORD CONNECTOR (6) through
GROMMET (8) as shown.
5. Connect SOLENOID CABLE (9) and POWER CORD
CONNECTOR (6) to EXTENSION CABLES (2) from
Faucet Sensor. Fig. 2d.
6. Replace ENCLOSURE COVER (1). Tighten cover
screws firmly.
Fig. 2
Fig. 2a
2
3
Fig. 2c
Fig. 2d
9
2
6
5
1
Fig. 2b
7
6
5
8
6
M 9 6 5 119 R E V. 1. 3
4