Operation
Use with YMP Plus/YBP Plus Clock/Signal Programmers
The tone generator can easily be triggered by the YMP Plus or YBP Plus Clock/Signal Programmers.
The figure below shows one way of wiring the tone generator to the clock/signal programmer. Setting
the schedule to trigger the circuits is described in the YMP Plus and YBP Plus Installation Manuals.
nNote: See the YMP Plus or YBP Plus Installation Manual before installation. Also, verify that the
master you have has the circuit option.
10
CIRCUIT
1
120vac
Input
AC
AC
NO
C
NC
IN
RTN
1
1
1
Black
Fused
120vac
White
Source
CIRCUIT
CIRCUIT
CIRCUIT
2
3
4
NO
C
NC
NO
C
NC
NO
C
NC
NO
2
2
2
3
3
3
4
4
4
Multi Tone Generator
CIRCUIT
CIRCUIT
CIRCUIT
CIRCUIT
5
6
7
C
NC
NO
C
NC
NO
C
NC
NO
5
5
5
6
6
6
7
7
7
8
8
C
NC
8
8
© American Time