ASTi AI-Delta 기술 사용 설명서 - 페이지 14

{카테고리_이름} ASTi AI-Delta에 대한 기술 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. ASTi AI-Delta 20 페이지.

AI-Delta Technical User Guide (Rev. A, Ver. 0)

4.1.2 Control input as analog input

To use the control input as an analog input, insert a resistance between the control input and con-
trol input ground pins. The four-channel selector knob, for example, contains a switch that
changes the resistance between the control input and control input ground pins.
4.2 Digital output
The digital output circuitry consists of an opto-isolated, solid-state relay for switching power to
external loads. The following table summarizes the AI-Delta's digital output opto-isolated field-
effect transistor (FET) values:
Type
Maximum continuous current rating
Maximum power dissipation
8
Figure 8: Analog In
Table 4: Digital output rating and dissipation
Copyright © 2017 Advanced Simulation Technology inc.
Opto-isolated FET
120 mA
300 mW