IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

This manual contains important safety instructions. Please follow all instructions carefully during installation.
Read this manual thoroughly before attempting to unpack, install or operate.
CAUTION-
To prevent the risk of fire or electric shock, install in a temperature and humidity controlled
indoor area, free of conductive contaminants.
CAUTION-
Risk of electric shock, do not remove the cover. No user serviceable parts. Refer servicing
to qualified service personnel.
CAUTION-
Risk of electric shock, hazardous live parts inside this UPS can be energized from the
battery supply even when the input AC power is disconnected.
CAUTION-
Risk of electric shock, Battery Circuit is not isolated from AC input, hazardous voltage may
exist between battery terminals and ground. Test before touching.
NOTICE-
The UPS is designed to be for use with computer loads only.
① Inspection
Inspect the UPS upon receipt. Notify the carrier
and dealer if there is damage. The package is
recyclable; save it for reuse or dispose of it
properly.
② Placement
⑤ Connect telephone /
Network Surge
protection
Connect a single line telephone or a 10 base-T /
100 base-T network cable into the RJ-45 / RJ-11
telephone / network surge protection "IN" jack on
the back of the UPS. Connect from the "OUT"
jack with telephone cable (supplied) or network
cabling (not supplied) to a fax modem or network
port.
IN
OUT
USER'S MANUAL
1000VA/1500VA
SETUP
③ Check the Site Wiring
Fault Indicator
only)
Caution:If the site wiring fault indicator lights,
get a qualified electrician to correct the building
wiring.
⑥ Connect Computer
Interface Port
Connect the optional interface cable to the USB
interface port on the back of the UPS. Connect to
the computer. See software document for
installation instruction. The optional RS232
interface may be instead of USB.
FRONT PANEL EXPLANATIONS

④ Connect the loads

First, connect the UPS with the AC Mains, then
(115V/120V
plug the loads into the output connectors on the
rear of the UPS. To use the UPS as a master
"On/Off" switch, make sure that all of the loads
are switch "On".
Caution:Do not connect a laser printer to the
outlets. These UPS outlets provide battery
power and surge protection to the equipment
when utility voltage is outside acceptable limits.

⑦ Operation Test

1. Connect the UPS to the wall receptacle.
(Optional)
2. Push on the Main Switch to check the Green
Line (
) LED is on.
3. Connect your computer equipment with sockets
of the UPS and pull off the input power cable of
the UPS from the wall receptacle to check if the
Inverter (
seconds. Meanwhile, please check if alarm
buzzer is beeping.
4. Try the field working condition by running some
application programs on your computer and
repeating step.
5. Check if the UPS is initiated properly to support
continuous operation.
IMPORTANT NOTICE:
6.
into the wall outlet to charge the UPS for over
8 hours before using the UPS.
STORAGE:
7.
Store at -15 to +30 °C (+5 to +86 °F), charge
the UPS battery every six months.
Store at +30 to +45 °C (+86 to +113 °F), charge
the UPS battery every three months.
192321942000004
)
LED are flashing every 3
Plug the UPS