1. SAFETY MEASURES
OVERLOAD PROTECTION:
The pump has a thermal overload safety device. In the event of any overhea- ting of the motor, this device automatically
switches off the pump. The cooling time is roughly 15 to 20 minutes, then the pump automatically comes on again.
If the overload cutout is tripped, it is essential to identify and deal with the cause of the overheating.
See Troubleshooting.
2. USE
Multi-purpose submersible pumps with a high degree of reliability and safety designed to circulate water in garden ponds, create
water falls and play water features.
Designed to work in both horizontal and vertical installations
NOVA 4100 models are suitable to pump clean water, without fibres and with particles with maximum diam. 0.393" (10 mm).
• Circulating water in Garden ponds.
• Water falls.
• Fountains.
• Water features.
The temperature of the fuid being pumped must never exceed 95°F (35°C).
The pump must not be used to pump salty water, sewage, inlammable, corro- sive or explosive liquids
(e.g. petrol, fuel, diluents), greases, oils or foodstuffs.
If the power supply cord has been damaged, it must be replaced by the manufacturer or his authorized
customer support service in order to avoid all risks.
Before starting the pump, make sure that:
• the voltage and frequency specified on the pump's nameplate coincide with those of the available power supply;
these pumps are designed for 115 Volt / 60 Hz or 230Volt / 60Hz operation.
• there are no signs of damage to the pump or its power cord;
• the electric connection is made in a dry place, protected against any risk of flooding;
• Conformity with local and State electric codes is mandatory. The National Electric Code requires that a ground fault
circuit interrupter (GFCI) be used in the branch circuit supplying sump, utility, effluent and all fountain pumps, pool
pumps and other pond equipment. Consult a li- censed electrician or your power company if in doubt.
Note: given the different provisions applicable to the safety of electric systems in different countries, make sure that the pump
system, as concerns its intended use, is in accordance with current local or state legislation.
3. STARTING THE PUMP
Insert the plug on the power cord in a suitable power socket.
Start the pump. 20 times per hour Max.
DAB PUMPS reserves the right to make modifications without notice