DAB VS 16/150 설치 및 유지 관리 지침 매뉴얼 - 페이지 9
{카테고리_이름} DAB VS 16/150에 대한 설치 및 유지 관리 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DAB VS 16/150 9 페이지.
FAULTS
The pump does not start
The system is noisy
The pump is noisy
The pump starts and then stops after a short
time
TROUBLESHOOTING
POSSIBLE CAUSES
No supply voltage.
Incorrect supply voltage.
Faulty capacitor ( single phase motors).
Rotor is blocked by deposits on the rotor.
Flow rate to high.
Air in the system.
Air in the pump.
Intake pressure too low.
Dirt or scale between the rotor and the stator
lining or between the impeller and pump
body.
REMEDIES
Check the electric connections and fuses.
Check the data on the plate and apply the
corect voltage.
Change the capacitor.
Select the maximum speed and/or free with a
screwdriver.
Select a lower speed.
Bleed the system.
Bleed the pump.
Increase the intake pressure.
Check the shaft is turning freely. Remove
any dirt and/or scale.