Door Controls DC-ONE V3 시작하기 및 문제 해결 매뉴얼 - 페이지 4

{카테고리_이름} Door Controls DC-ONE V3에 대한 시작하기 및 문제 해결 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Door Controls DC-ONE V3 13 페이지. Automatic door controller

Door Controls DC-ONE V3 시작하기 및 문제 해결 매뉴얼
 OPEN DECELERATION
open location, the motor is decelerated to halt motion. This
parameter controls the length of time for DECELERATION. this
is for HEAVY DOORS only. leave this set to default. If you need
to add some deceleration, Raising this value will increase
deceleration "ON" time (Not the amount of deceleration)
 CLOSE DECELERATION
close location, the motor is decelerated to halt motion. This
parameter controls the length of time for DECELERATION this is
for HEAVY DOORS only, leave this set to default. If you need to
add some deceleration, Raising this value will increase
deceleration "ON" time (Not the amount of deceleration)
 OPEN TORQUE
move the door throughout the entire open cycle. If the door will
not open properly or moves to slow. This is where to start. Turn
this up 10% at a time till the door moves through the cycle without
hesitation.
 CLOSE TORQUE This is where we set the controller power to
move the door throughout the entire close cycle. If the door will
not close properly or moves to slow. This is where to start. Turn
this up 10% at a time till the door moves through the cycle without
hesitation.
 OPEN CHECK TORQUE
power to move the door throughout the open check cycle. If the
door will not open completely. This is where to start. Turn this up
10% at a time till the door moves through the cycle without
hesitation.
 CLOSE CHECK TORQUE
power to move the door throughout the close check cycle. If the
door will not close completely. This is where to start. Turn this up
10% at a time till the door moves through the cycle without
 OPEN CHECK SIZE **
Open Speed to Check Speed. (inches from full open position)
 CLOSE CHECK SIZE **
from Close Speed to Check Speed. (inches from full closed
position)
 REDUCE OPEN SIZE **
Partial Open is selected on Multifunction Switch and an
Activation signal is received.
When the door reaches the check
When the door reaches the check
This is where we set the controller power to
This is where we set the controller
This is where we set the controller
This is where the door transitions from
This is where the door transitions
Door will only open to this setting if