6 Power Supply
With no locks connected, DC260 Access Control Unit power
consumption is 12V DC 25mA (quiescent ) and 60mA (operating).
Maximum power available for lock (from power supply provided) is
12V DC 1A (continuous).
Maximum lock relay contact rating is 24V DC 2A.
7 Door Monitor
Door monitor contact input, if fitted will re-lock the
door 2 seconds after door opens.
A monitored release or lock may be used in place of
the door contact.
N/C Orange
COM Purple
N/O Blue
Black GND
Red +12V DC
Brown D_IN
Yellow OPEN
Grey ALARM
White D1
Green D0
N/C Orange
COM Purple
N/O Blue
Black GND
Red +12V DC
Brown D_IN
Yellow OPEN
Grey ALARM
White D1
Green D0