Door-Gard 2000eM 설치 및 프로그래밍 - 페이지 2
{카테고리_이름} Door-Gard 2000eM에 대한 설치 및 프로그래밍을 온라인으로 검색하거나 PDF를 다운로드하세요. Door-Gard 2000eM 7 페이지.
Circuit Board Diagram
Main Wire Harness (P2)
Pin
Wire Color
Description
1
Red
V+ (Keypad Power)
2
Black
V- (Keypad Power)
3
White/Black
Wiegand Data 0/Secured Series Data
4
White/Yellow
Wiegand Data 1/Secured Series Data
5
Brown
Request to Exit (REX)/LED1
6
White/Orange Loop Common
7
White
Door Position Switch Input
8
Green
Main Relay Normally Open
9
Blue
Main Relay Common
10
Gray
Main Relay Normally Closed
Auxiliary Relay Wire Harness (J2)
Pin
Wire Color
Description
1
Green
Aux Relay Normally Open
2
Blue
Aux Relay Common
3
Gray
Aux Relay Normally Closed
2
Note: J3 is for use
only with the 2000-8EX
Output Module.
2000e & 2000eM Keypad Installation & Programming
UL Requirements
The 2000e/2000eM keypad is a UL Listed access control unit. This
section contains information regarding the requirements necessary to
meet UL compliance.
Wiring methods shall be in accordance with the National Electrical
Code (ANSI/NFPA70), local codes, and the authorities having
jurisdiction.
All wires and cables used must be a minimum of 22 AWG, stranded
and shielded UL Listed and/or recognized wire suitable for the
application. In addition, input and output cables that extend from the
unit must be shielded, twisted pair. Ground the shield only at one end,
usually the circuit end.
All interconnecting devices (ie. door contacts, REX, locking devices,
alarm devices, doorbell, etc.) must be UL Listed.
A UL Listed access control power limited power supply, capable of 4
hours standby, must be used to power the keypad.
A minimum of three user codes must be programmed for controlling
access.
The following Wiegand card formats were not evaluated by UL: 28-bit,
29-bit, 30-bit, 31-bit, 32-bit or 36-bit (formats 2-8 from wiegand format
chart. UL did evaluate the 26-bit card format (format 1).
8-Bit Burst Mode was not evaluated by UL.
Installing a Tamper Switch
To meet UL requirements, a UL Listed tamper switch must be
installed in a UL Listed single-gang box used for mounting the
keypad. The tamper switch must activate if the keypad is removed
from the box and must disconnect power from the lock. The lock
must be a fail-secure device, meaning the lock remains locked
when power is removed.
In addition, once the tamper device is activated, it must be
confi gured so that it can only be reset from within the protected
area. Only a Sentrol 3012 or Sentrol 3025T tamper switch can be
used. The diagrams below show the suggested mounting location
for each device.
6-104402 X2