DoorHan SHAFT-30 설치 매뉴얼 - 페이지 6

{카테고리_이름} DoorHan SHAFT-30에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DoorHan SHAFT-30 8 페이지. Ip65/60 ip65
DoorHan SHAFT-30에 대해서도 마찬가지입니다: 매뉴얼 (12 페이지), 설치 및 운영 매뉴얼 (12 페이지)

DoorHan SHAFT-30 설치 매뉴얼

ELEcTrIcaL

6
J1
inputs terminal board and power supply to accessories
J2
connector for radio receiver (see note)
J3
(not used)
J4
motor terminal board
J5
230 V ac power supply terminal board
J6
limitswitch terminal board
lED
signalling key
tR1
transformer
F1
5a  250 V(motor protection)
F2
selfresetting (accessories protection )
to select the function logic, press the sW1 pushbutton the number of times equal to the number of the required logic, irrespective of the
current logic and the door status. the interval between the pulses must be less than 1 second.
the selected logic is then continuously displayed by the Dl1 lED, which flashes once a second at 3 sec intervals, equal to the number of
the required logic. to select the logics, press sW1 the number of times indicated in the table below:

7. Adjustment Limit switch

Rough adjusting (setting of the close limit)
Check that the operator has firmly
installed, close the door to fully closed
position and observe the rotating
direction of red limit cams during
closing. loose the screws of red limit
cams, then turn two cams in the same
direction until the limit switches click,
finally tighten the screws.
if the gap between the door and its
bottom position is larger than 20mm,
repeat this step until the door is less
than 20mm from the closed position.
6
in s ta l l at i o n ma n u a l s H aF t -3 0