2. OPERATOR PROGRAMMING
2.1. BASIC PROGRAMMING
To perform the basic programming do the following:
1. Enter the basic programming menu by pressing the «P» button. The left part of the display will show «P», and the right
part will show the menu item according to the programming table (see Basic Programming table).
2. Pressing the buttons «+» or «-» select the required menu item.
3. To enter the menu press «P», the value of adjusted parameter will start flashing on the display.
4. Pressing the buttons «+» or «-» change the value of the adjusted parameter.
5. Press «P» to save new value and exit to main menu.
6. Having performed the adjustment of all the required parameters press «R» to exit the programming menu.
NOTE:
Press «R» if you need to exit to main menu without saving the parameters.
Display
Function
Operation mode:
P0
Y — operation on time; n — operation on limit switches
Delay of 1st leaf closing:
P1
1 — 1 sec; 2 — 5 sec; 3 — 10 sec; 4 — 15 sec; 5 — 20 sec; 6 — 25 sec; 7 — 30 sec; 8 — 35 sec;
9 — 40 sec
Delay of 2nd leaf opening:
P2
1 — 1 sec; 2 — 2 sec; 3 — 3 sec; 4 — 4 sec; 5 — 5 sec
P3
Control board setting (force, deceleration and operation time)
Automatic gate closing:
P4
0 — off; 1 — in 10 sec; 2 — in 20 sec; 3 — in 30 sec; 4 — in 60 sec; 5 — in 90 sec; 6 — in 120 sec;
7 — in 180 sec; 8 — in 360 sec; 9 — in 420 sec
Auxiliary lighting (19-20 terminals):
0 — flashing during closing, solid during opening.
P5
Switching on during any gate movement and switching off after stopping: 1 — in 10 sec; 2 — in 20 sec;
3 — in 30 sec; 4 — in 60 sec; 5 — in 90 sec; 6 — in 120 sec; 7 — in 180 sec; 8 — in 360 sec; 9 — traffic light mode
is activated only in the open position of the limit switches (does not work without limit switches)
P6
Cycles counter (one division corresponds to 1 000 cycles)
2.2. OPERATOR SETTING
Learning process depends on which operation mode («P0» menu item), manual or automatic, you have selected.
2.2.1. Manual learning
1. Close the gate and lock the drives (if the ledge is available, adjust the leaves deceleration).
2. Enter the Basic Programming menu (see Basic Programming section) and select «P3» item.
3. Press the «P» button. The leaf 1 will start to open* and the display will show blinking «Ln».
4. As soon as leaf 1 reaches the OPEN limit press the «+» button.
5. Leaf 2 will start to open (see NOTE below).
6. As soon as leaf 2 reaches the OPEN limit press the «+» button.
7. Leaf 2 will start to close (see NOTE below).
8. As soon as leaf 2 reaches the CLOSE limit press the «+» button.
9. Leaf 1 will start to close (see NOTE below).
10. As soon as leaf 1 reaches the CLOSE limit press the «+» button.
11. Two short beeps will sound, and the program will automatically exit the programming mode.
NOTE:
To set the deceleration before the end position, press the «+» button while the leaf is moving.
16
OPERATOR PROGRAMMING
Defaul
n
2
2
Ln
0
0
00