QUICKSTART "BASIC" GUIDELINES FOR MODEL 9000 - DIP-SWITCH AND WIRING REFERENCE
Model 9000 is intended for installation only on slide gates used for vehicles.
Pedestrians must be supplied with a separate access opening.
For safety and installation instructions, please refer to the Installation/Owner's manual.
SW 1 DIP-Switches
Switch
Function
Setting
Primary
Opening direction
Opening direction
1
Operator
using ON setting.
using OFF setting.
Opening
Direction
Secondary
Opening direction
Opening direction
Operator
using ON setting.
using OFF setting.
2
Opening
Direction
OFF
The output wired to terminal #4 becomes the output from the exit loop detector
Exit Loop Port
Output
3
plugged into the EXIT Loop port.
Full Open Input
Normal Setting. Terminal #4 is a normal full open input.
ON
Auto-close timer is OFF. Manual input required to close gate.
OFF
Auto-Close
4
Timer
ON
Normal Setting. Auto-close timer is ON. Adjustable from 1-23 seconds.
Normal Setting. Input to terminal #6 and reverse loop will reverse gate during
OFF
Reverses Gate
close cycle.
5
Input to terminal #6 and/or reverse loop will stop gate during close cycle – gate will
ON
Stops Gate
continue to close after input to terminal #6 and/or reverse loop are cleared (Helps
prevent tailgating).
Single Operator
OFF
Normal Setting. Switch must be OFF for single operator.
6
Dual Operators
ON
Switch must be ON when primary/secondary (dual) gates are used.
Normal Setting. Relay activates when gate is at open limit.
7-OFF
8-OFF
Relay activates when gate is not closed.
7-OFF
8-ON
7 and 8
Relay
Relay activates when gate is opening and open.
7-ON
8-OFF
Relay activates during opening and closing cycle.
7-ON
8-ON
Note: After a DIP-switch setting is changed, power must be turned
OFF and then turned back on for the new setting to take affect.
SW 2 DIP-Switches
Switch
Function
Setting
Normal Setting. Timer will function normally.
OFF
1
Quick-Close
ON
Opening gate will stop and begin to close as soon as all reversing inputs (Reverse
Timer Override
loops, photo sensors) are cleared regardless of the distance the gate has opened.
Normal Setting. Magnetic lock is not used.
OFF
2
Magnetic lock
Magnetic lock is used and connected to terminals 9 and 12.
ON
3
Normal Setting. Switch 3 MUST be turned ON for Model 9000 operator.
ON
4
Normal Setting. Switch 4 MUST be turned OFF for Model 9000 operator.
OFF
Description
Changes direction operator will cycle open
upon initial AC power up and open command.
Changes direction operator will cycle open
upon initial AC power up and open command.
P2
FIRE
EXIT
LOOP
POWER
TIME
DELAY
REV SENSE
SECONDARY
REVERSE
LOOP
Description
Important:
Controls intended for user activation must be located at least six (6) feet away from any moving part of the gate and where
the user is prevented from reaching over, under, around or through the gate to operate the controls. Emergency access controls only
accessible by authorized personnel (e.g., fire, police, EMS) may be placed at any location in the line-of-sight of the gate.
4-Pin Non-Removable Terminal
3-Button Control Station
Use a standard 4-wire 3-button control station. DoorKing's
3-wire 3-button control station cannot be used.
3-Pin With
#1 Open N.O.
Jumper
E N
O P
#2 Close N.O.
S E
C L O
#3 Stop N.C.
O P
S T
Place jumper
#4 Com
on bottom
2 pins when
using 4-pin
terminal.
To #4 Com
Fire Dept Open
Supplied
Wire Harness
FIRE
1
Com
2
Full
Open
Terminal #3 Note: Exceeding 250 mA of power from this terminal may cause the circuit board transformer to overheat,
2
24
3
causing intermittent problems.
1
VAC
2
4
IMPORTANT:
3
4
to each input. An OPTIONAL Expansion Kit (sold
4
5
separately) will allow connection for additional devices.
1477-010
SW1
ON
5
6
1
2 3 4
UL 325
UL 325
6
Terminal
7
DIP switches
Open Beam necessary when area between
1
OB
7
gate and wall is between 2 1/4" and 16".
8
2
CB
8
UL 325 DIP-Switches
3
OE
9
24
ON
4
CE
VDC
5
G
1
10
6
G
REV SENSE
11
PRIMARY
NC
NO
12
OPEN Edge/Beam REVERSE
CLOSE Edge/Beam REVERSE
13
Com
14
15
#9 Normally
16
Close
24 Volt 1 amp max.
17
18
19
20
Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists.
20
4405-018
The operator will NOT run without one or more monitored type B1 or B2 external entrapment protection devices
in EACH direction of gate travel (minimum of 2 external devices required).
UL 325 August
2018 Standard
Normally Closed
Interlock Switch
Operator Cycling
N.C.
Note: When
Com
using 3-button
N.O.
control station
Lock Engaged
AND interlock
switch together,
Operator Stopped
3-Pin
#3 terminal
N.C.
(N.C.) must be
Com
Remote
wired in series.
Terminal
N.O.
To #3 Stop N.C.
Lock Disengaged
Gate will ONLY OPEN when this device is activated by authorized personnel ONLY (fire,
police, EMS) and operator has power. Alarm will sound during entire open cycle.
Operator will then go into a hard shutdown once fully opened. Operator MUST be reset to
function normally again. This device MUST be mounted in the line-of-site of gate so
authorized personnel can monitor gate movement.
Dual Gate Operators Note: Connect device to BOTH operators, both gates will fully open.
Activation Note: Activation of this device will OPEN gate regardless of the status of the
open direction monitored external entrapment protection device(s). If gate is opening,
and the operator's inherent entrapment protection system detects an obstruction, the
operator will reverse approx. 2 inches and go into a hard shutdown. Operator reset
button MUST be pushed to function again OR cycle operator's power.
External Entrapment
Only 1 monitored Device can be connected
Protection Devices
Close Beam
Wall
Filler Post If necessary
Open Beam
Open Edge
Closed Gate
DIP-switches MUST be turned ON
for each device wired to terminal.
2 3 4
UL 325 Terminal
1
OPEN Beam STOP
N.C.
UL 325 switch 1
2
N.C.
CLOSE Beam REVERSE
UL 325 switch 2
3
N.C.
N.C.
UL 325 switch 3
4
N.C.
UL 325 switch 4
5
Connect ONLY MONITORED
(Common) Ground
Devices
6
(Common) Ground
IMPORTANT:
Photo sensors must use
Magnetic Lock
Normally Closed (NC) contacts with the beam
Power (24-Volt DC) and
set for light operate (relay activated when
beam is not obstructed). Some manufacturer's
logic output. Power is shut
photo sensor contacts are labeled as Normally
off .5 sec. prior to gate
Open (NO) but their relay functions the same
starting and remains off
way as described above. See specific
while gate is opening and
manufacturer's wiring manual for more
information about their specific relay function.
in the open position.
120 S. Glasgow Avenue
Inglewood, California 90301
U.S.A.
3-Wire Radio
Receiver
1
2
3
Power is limited
to 250 mamps.
r
Po
we
Type of wiring to be used on ALL
external devices:
A) Type CL2, CL2P, CL2R, or CL2X.
B) Other cable with equivalent or better
electrical, mechanical, and flammability
ratings.
#2 Normally Open
Telephone
Entry
Stand-Alone
Key Switch
Stand-Alone
Keypad
Stand-Alone
Card Reader
Note: All stand-alone
and telephone entry devices must
use a separate power source.