DoorKing 1620-083 설치 매뉴얼 - 페이지 6

{카테고리_이름} DoorKing 1620-083에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DoorKing 1620-083 16 페이지. Surface mount vehicular lane barrier accessory

IMPORTANT: Installation of Octagon Arm with Reverse/LED Edge, Traffic Light and Photocell is REQUIRED.

Layout

6"
6"
IMPORTANT: Secondary barrier arm is a fixed distance for each lane width model
and this will determine the specific placement of the support post assemblies.
36"
6"
End
Cap
Arm Channel Section
2 ft or 3 ft
12"
1"
Use 3000 psi
reinforced concrete. It MUST be flat.
DO NOT install directly on asphalt.
Secondary Barrier Arm Counterweight Assembly
9 ft Lane: Use 30 counterweights (15 on each side)
10 ft Lane: Use 32 counterweights (16 on each side)
12 ft Lane: Use 32 counterweights (16 on each side)
14 ft Lane: Use 34 counterweights (17 on each side)
t
i g h
w e
t e r
u n
C o
t e
P l a
Same number of counterweights
MUST be on each side of plate.
1620-065-G-8-20
Lane Width
Varies depending on 1620 Model selected.
One-Way Traffic Direction ONLY!
Secondary Barrier Arm (Up Position)
Traffic Direction
r m
y A
d a r
n .
t i o
c o n
o s i
S e
P p
i n U
H u
Ball Joint Fixture
Adjustment
Secondary
Arm Rod
TOP
t
i g h
w e
t e r
u n
C o
Note: Allow an extra 6
inches of concrete
around all structures min.
6"
6"
Secondary Arm Assembly
Connect secondary arm bracket and rod assembly on
opposite side of 1601's octagon arm as shown.
Adjust arm position using ball joint fixtures so arm lays
completely in channel when down (see next page).
b
Secondary
Arm Rod
y
d a r
c o n
BOTTOM
S e
A r m
t
c k e
B r a
Adjustment
Ball Joint Fixture
3
34.5"
12"
7.76"
14.74"
Secondary Arm
Assembly
6"
1601 Barrier
Operator
Photo Beam
1601 Octagon Arm
6"
Test hub UP and DOWN
1"
position before installing
secondary arm bracket.
Arm DOWN
90°
Approx. 60°
Secondary Arm
in UP position.
Counterweight
Assembly
Drawings NOT to scale.
6"
39.5"
6"
Traffic
6"
Light
Secondary arm
bracket bolted
to hub.
WARNING
MOVING ARM
can
cause vehicle damage,
serious injury or death.
STAY CLEAR
of arm
at all times.
NO:
Pedestrians
Bicycles
Motorcycles
CONFORMS TO
ANSI/UL-325
53382
CERTIFIED TO
CAN/CSA C22.2 NO. 247
VEHICULAR GATE OPERATOR
CLASS
HP
Arm
MODEL
SERIAL
VOLTS
PHASE
AMPS
60 Hz
MAX GATE LOAD
DoorKing, Inc., Inglewood, CA
UP
Moving Gate Can Cause
Serious Injury or Death
KEEP CLEAR! Gate may move at any time
without prior warning.
Do not let children operate the gate or play
in the gate area.
This entrance is for vehicles only.
Pedestrians must use separate entrance.
Ball Joint Fixtures